CC1 AC Contactor for 9-95A

Short Description:

AC contactors are used in connecting/disconnecting the line and frequently controlling motors and other equipment.It controls the large current with small current and plays a certain role in overload protection when working with the thermal relay.


Product Detail

Product Tags

Description

Application: remote making & breaking circuits; protect circuit from over-load when assembling with thermal over-load relay; frequent start-up and control of AC contactor;
Electric value: AC50/60Hz, 690V, up to 95A; Utilization category: AC-3, AC-4;
Altitude: ≤2000m;
Ambient temperature: -5℃~+40℃; Mounting category: Ⅲ;
Mounting conditions: inclination between the mounting plane and the vertical plane should not exceed ±5°;
Standard: IEC/EN 60947-4-1. IEC/EN 60947-5-1.
Control Coil Voltage(AC Coil Operation)

Volts(VAC)

24

36

42

48

110

127

220

230

240

380

415

440

480

500

600

 Code

50Hz

B5

C5

D5

E5

F5

G5

M5

P5

U5

Q5

N5

R5

-

S5

Y5

60Hz

B6

-

D6

E6

F6

G6

M6

-

U6

Q6

-

R6

T6

-

-

50/60Hz

B7

-

D7

E7

F7

-

M7

P7

-

Q7

N7

R7

-

-

-

Control Coil Voltage(DC Coil Operation)

Volts(VDC)

12

24

36

48

110

220

Code

JD

BD

CD

ED

FD

MD

CC1

Technical Specification

Standard IEC/EN60947-4-1 IEC/EN60947-5-1
Model No.

CC1-09

CC1-12

CC1-18

CC1-25

CC1-32

Rated Conventional Heating Current

Ith (A)

20

20

32

40

50

Rated Voltage Ui(V)

Ui(V)

690

690

690

690

690

Rated Operation CurrentUe=380/415V

AC-3 Ie(A)

9

12

18

25

32

AC-4 Ie(A)

3.5

5

7.7

8.5

12

Power Controlled 3ph cage MotorAC-3

220/240V KW

2.2

3

4

5.5

7.5

380/415V KW

4

5.5

7.5

11

15

660/690V KW

5.5

7.5

10

15

18.5

Electrial life(x103 operations)

AC-3

1000

1000

1000

1000

800

AC-4

200

200

200

200

200

Mechanical life(x106 operations)

10

10

10

10

8

 Matched Fuse

Size

RT16-00

RT16-00

RT16-00

RT16-00

RT16-00

A

20

20

32

40

50

Main circuit

3P or 4P

Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A   1NO or 1NC
Standard IEC/EN60947-4-1 IEC/EN60947-5-1
Model No.  

CC1-40

CC1-50

CC1-65

CC1-80

CC1-95

Rated Conventional Heating Current

Ith (A)

60

80

80

100

125

Rated Voltage Ui(V)

Ui(V)

690

690

690

690

690

Rated Operation Current

Ue=380/415V

AC-3 Ie(A)

40

50

65

80

95

 

AC-4 Ie(A)

18.5

24

28

37

44

Power Controlled 3ph cage Motor

AC-3

220/240V KW

11

15

18.5

22

25

 

380/415V KW

18.5

22

30

37

45

 

660/690V KW

30

33

37

45

45

 

Electrial life(x103 operations)

AC-3

800

600

600

600

600

 

AC-4

150

150

150

100

100

Mechanical life(x106 operations)  

8

8

8

6

6

 

Matched Fuse

Size

RT16-00

RT16-00

RT16-00

RT16-00

RT16-00

 

A

63

80

80

100

125

Main circuit

3P or 4P

Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A  

1NO+1NC

 

 

Model

Cabling cross section(Cu)

 

screw size

 

Tightening torque(N.m)

   

Number of piece

Flexible cable with cold-pressed socket(mm2 )

Flexible cable without cold-  pressed socket(mm2 )

 

Inflexible cable(mm2 )

   
CC1-09

1~2

2.5

4 4

M3.5

0.8

CC1-12

1~2

2.5

4 4

M3.5

0.8

CC1-18

1~2

4

6 6

M3.5

0.8

CC1-25

1

4

10 6

M4

1.2

 

2

4

6 6

M4

1.2

CC1-32

1

4

10 6

M4

1.2

 

2

4

6 6

M4

1.2

CC1-40

1

10

16 10

M4

3.5

 

2

10

10 10

M8

3.5

CC1-50

1

16

25 25

M8

3.5

 

2

16

16 -

M8

3.5

CC1-65

1

16

25 25

M8

3.5

 

2

16

16 -

M8

3.5

CC1-80

1

50

50 50

M8

3.5

 

2

25

35 -

M10

4.0

CC1-95

1

50

50 50

M10

4.0

 

2

25

35 -

M10

4.0

ac
acc

1.L: in main circuit, the distance between terminals and plate;
2.P: in main circuit, the distance between two phases;
3.S: in main circuit, the width of contacting plate.

Model

A max

B max

C max

D max

E max

a

b

Φ

L

P

S
CC1-09(Z)~12(Z)

47

76

82(116)

120.5(154.5)

140.5(174.5)

34/35

50/60

4.5

60(95)

10.5

8.6
CC1-18(Z)

47

76

87(122)

125.5(160.5)

145.5(180.5)

34/35

50/60

4.5

61(96)

11.3

10.4
CC1-25(Z)

57

86

95(131)

133.5(169.5)

153.5(189.5)

40

48

4.5

70(107)

13.2

11.7
CC1-32(Z)

57

86

100(138)

138.5(176.5)

158.5(196.5)

40

48

4.5

71.6(120)

14.5

13
CC1-4011(Z)~6511(Z)

77

129

116(173)

154.5(211.5)

174.5(231.5)

40

100/110

6.5

78(135)

20

8.6
CC1-4004/4008(Z)~6504/6508(Z)

84

129

116(173)

154.5(211.5)

174.5(231.5)

40

100/110

6.5

78(135)

20

8.6
CC1-8011(Z)~9511(Z)

87

129

127(188)

165.5(226.5)

185.5(246.5)

40

100/110

6.5

83(140)

23.5

12
CC1-8004/8008(Z)~9504/9508(Z)

96

129

127(183)

160.5(221.5)

180.5(241.5)

40

100/110

6.5

83(140)

23.5

12